View single post by RegUS_PatOff
 Posted: Mon Jun 29th, 2009 04:49 am
PM Quote Reply Full Topic
RegUS_PatOff



Joined: Sat Sep 24th, 2005
Location: Milwaukee, Wisconsin USA
Posts: 9067
Status: 
Offline
vinmoe wrote: The instructions for this forum said to leave out the 110. that's why I did not post it.

The full # is 110.76932692....

What instructions...

I thought I tried 110.76932692 .. oh well..

Not much else it could be...

Dryer Vent

Vent should be rigid metal.

Short lengths of flexible metal may be OK, if not crimped when moving the Dryer into place.

NO plastic

NO PVC

NO screws

Foil Duct Tape is OK.

With an empty load, Timed Dry, High Heat, the vent temperature should cycle somewhere between 135F and 160F



____________________

RegUS_PatOff http://www.youtube.com/watch?v=oPAY2LsKVEw

my video production: “Easter Seals Walk With Me” (also in HQ) http://www.youtube.com/watch?v=-EBiLyYXMiA

Upon leaving this Earth "Do you want the Smoking or Non-Smoking section ?"